Loft insulation depth
Loft insulation thickness: how much do you need?
Most UK lofts are insulated to a depth of 270mm when they use mineral wool, but the right figure depends on the material, what is already up there and whether you want to board the loft for storage. This guide sets out the published figures and how to check your own loft.
Written and reviewed by the Roof Insulation Solutions team. Sources checked 25 November 2026.
The short answer
How thick should loft insulation be in the UK?
The recommended loft insulation thickness in the UK is 270mm of mineral wool, laid between and across the ceiling joists. Which? (6 October 2026) gives that figure and adds that other materials need different depths, because some insulate better per millimetre than others.
Building regulations make the same point in a different way. Approved Document L, Volume 1 (2021 edition, incorporating 2023 amendments) sets an improved U-value of 0.16 W/m²K for a roof being renovated (Table 4.3), and its Table C1 gives "250mm mineral fibre or cellulose fibre" laid between and across the joists as the typical way to reach it in a cold loft.
These are the rules in England. Wales, Scotland and Northern Ireland have their own building regulations.
Depth and U-value
How does loft insulation depth affect the U-value?
More depth gives a lower U-value, which means less heat escaping through the ceiling. In Knauf Insulation's published table (November 2026), 270mm of its Loft Roll 44 glass mineral wool reaches 0.16 W/m²K. Thermafleece's guide shows 240mm of its sheep's wool roll (CosyWool Roll, formerly EcoRoll) reaching the same 0.16 W/m²K.
| Material | Between joists + over joists | Total depth | U-value (W/m²K) |
|---|---|---|---|
| Glass mineral wool, Knauf Loft Roll 44 | 100mm + 170mm | 270mm | 0.16 |
| Glass mineral wool, Knauf Loft Roll 44 | 100mm + 200mm | 300mm | 0.15 |
| Glass mineral wool, Knauf Loft Roll 44 | 100mm + 250mm | 350mm | 0.13 |
| Glass mineral wool, Knauf Loft Roll 40 | 100mm + 150mm | 250mm | 0.16 |
| Glass mineral wool, Knauf Loft Roll 40 | 100mm + 200mm | 300mm | 0.13 |
| Sheep's wool roll | 100mm + 140mm | 240mm | 0.16 |
| Sheep's wool roll | 100mm + 200mm | 300mm | 0.13 |
Sources: Knauf Insulation, Loft Rolls typical U-values (November 2026), which assumes 100 x 47mm joists at 400mm centres, 12.5mm plasterboard and a cold ventilated roof; and the Thermafleece loft installation guide (2026) for its sheep's wool roll, rated at 0.039 W/mK. These are the makers' own figures for typical build-ups, not a calculation for your house.
Loft Roll 40 insulates slightly better than Loft Roll 44, so it needs 20mm less to reach 0.16. If someone quotes you a depth, ask which product it is and what U-value it gives. Our guide to sheep's wool loft insulation compares the two materials on cost, fire rating and handling.
Older lofts
Is 100mm of loft insulation enough?
100mm of loft insulation is well short of today's guidance. Approved Document L's Table C1 treats an existing layer of 50mm to 100mm in good condition as a case for topping up "to at least 250mm" of mineral fibre. Thermafleece's table shows 100mm of old insulation plus 140mm of wool reaching 0.17 W/m²K.
A top-up saves less than insulating an empty loft. Energy Saving Trust estimates published by Which? (6 October 2026) put the yearly saving for topping up from 120mm to 270mm at about £17 for a semi-detached house, against about £190 for insulating one from nothing. The full table is on our loft insulation installation page.
If cost is holding you back, our guide to loft insulation grants explains what help is still available.
| Existing | Added | Total | U-value |
|---|---|---|---|
| 75mm | 140mm | 215mm | 0.18 |
| 100mm | 140mm | 240mm | 0.17 |
| 100mm | 200mm | 300mm | 0.13 |
| 150mm | 140mm | 290mm | 0.15 |
Check your loft
How do you measure loft insulation depth?
To measure loft insulation depth, push a ruler or tape down through the insulation until it touches the ceiling below, then read the top surface. Do this in several places. Which? (October 2026) advises checking whether you have any insulation and how much before deciding, since a top-up is a different job from starting again.
- 1
Get in safely
Use a torch, gloves and a dust mask, and stand or kneel on the joists or a board across them. The plasterboard between joists won't take your weight.
- 2
Measure in three or four spots
Check near the hatch, in the middle and towards the eaves. Old insulation is often thinner at the edges, where it is hardest to reach.
- 3
Measure the joists
Thermafleece's guide says to measure from the top to the bottom of a joist, and the gap between joists centre to centre. That tells you what fits in the base layer.
- 4
Look at the condition
Note any patches that are flattened, damp, stained or missing, and any boards already laid over the insulation.
If the insulation sits level with the top of the joists or below it, you are probably at 100mm or less. If something looks wrong, a photo from the hatch sent through our loft insulation enquiry form is a good place to start.
Topping up
How do you top up existing loft insulation?
Topping up loft insulation means filling any gaps between the joists, then laying a second layer across them at right angles. Which? (6 October 2026) describes exactly that, and Thermafleece says cross-laying covers the joists and reduces heat lost through the timber.
The old layer can usually stay. Thermafleece's guide says new wool can go on top as long as the old material "is in good condition and is not hiding any damp or structural damage". If it is wet, mouldy or soiled, it should come out and the cause should be fixed first.
- Leaks, damp spots and rotten timber sorted before anything goes down
- Cables kept on top of the insulation, as Which? advises, and never buried
- Downlights covered with suitable loft caps or covers
- No insulation directly under a cold water tank, so a little warmth reaches it
- Insulation kept at least 150mm from chimneys and hot flues (Thermafleece)
Points from the Thermafleece installation guide (2026) and Which? (October 2026).
Storage
Can you put boards on top of loft insulation?
Board over insulation only on raised supports that leave the full depth and an air gap underneath.
You can put boards over loft insulation, but not straight onto it. Which? (October 2026) says 270mm over the joists "would make it impossible to lay boards on top", and that squashing mineral wool "will reduce its insulation properties". The usual fix is to raise the floor on legs or spacers screwed to the joists.
Why does compressing insulation reduce performance?
Boards or boxes pressing on loft roll make it thinner, so the depths in the tables above no longer apply. Which? tells installers to "be careful not to compress the insulation".
Loft legs and raised platforms
Loft legs screw onto the joists and hold the boards above the insulation. LoftZone's FAQ (checked November 2026) gives its StoreFloor supports as 279mm tall. Thermafleece's guide suggests filling between the joists, fitting the legs, then cross-laying the top layer between them with no gaps.
Condensation under boards
Which? describes raising the floor to fit the insulation "plus a ventilation gap". LoftZone says the air gap under its boards "allows for ventilation, removing any possible moisture build-up on the underside of the boards". Approved Document L's Table C1 asks for condensation risk to be assessed whenever loft insulation is upgraded.
How much can loft joists hold?
Ceiling joists hold up a ceiling, not a floor. LoftZone recommends no more than 25kg of stored items per square metre, plus one person reaching them, and wooden joists at least 32mm wide. If your joists are thin or damaged, get them checked before storing anything heavy.
We can talk through whether a raised storage area suits your loft when we look at the insulation.
Ventilation
Should loft insulation go right into the eaves?
Loft insulation should reach the edge of the loft over the outside walls, but it must not block the vents at the eaves. The Planning Portal (checked November 2026) says "care should be taken not to block any ventilation at the edges (eaves)", which matters more as the insulation gets deeper.
Thermafleece's guide says roofs with impervious felt or sarking boards need adequate ventilation at the eaves, and that blocked eaves should be cleared before you start.
Had spray foam taken out?
Spray foam on the underside of the roof sometimes covers the eaves. Once it's gone, the airflow and the timbers need checking before any new depth goes down. Our guide to what goes back in after spray foam removal covers that inspection.
FAQs
Loft insulation depth questions
Answers based on the sources linked above.
Not sure what's in your loft?
Tell us what you can see and we'll explain the options for your roof.
Get adviceCan you have too much loft insulation?
Extra depth keeps lowering the U-value, as Knauf's table shows, but each step saves less. The real limits are practical: deep insulation that blocks the eaves, buries cables or leaves no room for a raised floor causes more problems than it solves.
Is 200mm of loft insulation enough?
It's below the usual 270mm figure for mineral wool. Knauf's table reaches 0.16 W/m²K at 250mm to 270mm depending on the roll. A top-up layer laid across the joists is often all that's needed.
Does old loft insulation need removing before a top-up?
Not usually. Thermafleece says new insulation can go on top if the old layer is in good condition and isn't hiding damp or structural damage. Wet, mouldy or badly soiled insulation should come out first.
How high do loft legs need to be?
High enough to clear the full depth of insulation over the joists with an air gap above it. LoftZone's standard supports are 279mm tall. Check the height of any product against the depth you plan to fit.
Do I need building regulations approval to top up loft insulation?
Usually not, if you are only adding insulation. In England, work that consists solely of loft insulation is exempt from building control notification under Schedule 4 of the Building Regulations 2010, unless it is being done to meet another requirement. The Planning Portal says loft insulation must still meet the minimum energy efficiency values in the Approved Documents. When a roof is being renovated in England, Approved Document L sets an improved U-value of 0.16 W/m²K. Check with your local building control if you're unsure what applies to your work.