Once spray foam is off, the roof gets its first proper look in years. This guide covers what should be checked, which repairs come up, how to choose between insulating the loft floor or the roof slope, and where building regulations come in.

Written and reviewed by the Roof Insulation Solutions team. Sources checked 25 November 2026.

The inspection

What happens after spray foam is removed?

After spray foam is removed, the exposed roof is inspected before anything new goes in: timbers, the membrane or felt, battens, eaves and ridge ventilation, and any cables the foam hid. The HSE report rates a roof high risk where over 25% decay is predicted in the outer timber within five years, so the timbers come first.

What turns up decides the next step. Which foam you had, open-cell or closed-cell, affects how it comes off and what needs checking.

Exposed old roof timbers in a loft after insulation has been cleared

Timber checks after removal

  • Damp staining
  • Soft or decayed wood
  • Foam residue left behind

Rafters, purlins and joists are checked for moisture marks, softness and decay. The 2024 government-commissioned report below measured spray foam risk by predicted decay in the outer timber over five years.

Rafters and roof underlay seen from inside a loft

Membrane and batten checks

  • Felt or breathable membrane?
  • Tears and holes
  • Battens and tile fixings

The underlay is identified and checked for tears, especially where foam was bonded to it. Where foam was sprayed straight onto the back of tiles or slates with no underlay at all, the battens and fixings get a close look too.

A dark loft space with roof timbers and limited light

Ventilation and wiring checks

  • Eaves and ridge airflow
  • Blocked vents
  • Cables, pipes and fittings

Foam sometimes covers the eaves vents, so the airflow paths are opened up and checked. Cables that were buried in foam are looked at, and anything needing an electrician is flagged before insulation goes over it.

Roof membrane

Do I need to replace the roof membrane after spray foam removal?

Not always. An intact roof membrane or felt can usually stay after spray foam removal. It needs repair or replacement where removal reveals tears or long-term damage, or where there was never an underlay. Under bitumen felt, BS 5250:2021 calls for a ventilated gap of at least 25mm, plus 15mm for drape, above new insulation.

Keep a sound membrane, repair a damaged one, and let its type decide how the new insulation is fitted.

Marley (2026) calls the membrane a secondary weatherproof barrier under the tiles. Breathable membranes are now the most common type, and non-breathable ones should be part of a system with traditional ventilation.

The HSE report on spray foam in sloped roofs (dated February 2024, published 28 March 2024), started by DLUHC, summarises BS 5250:2021. Under a high resistance underlay such as bitumen felt, it calls for a ventilated gap of at least 25mm plus 15mm for drape above the insulation, with an air and vapour control layer on the warm side.

  • Bitumen felt (high resistance): needs a ventilated gap above the insulation, open at high and low level
  • Breathable membrane (low resistance): BS 5250 options still include a vapour control layer on the warm side
  • Foam sprayed onto tiles or slates: the HSE report found high risk in every scenario it modelled
  • Replacing the membrane from outside means lifting the roof covering, which is a bigger job

Membrane work from outside

A GOV.UK leaflet on repairs to your home (last updated 2014) lists replacing roof coverings on pitched roofs as work you need to tell building control about, unless your roofer is in a competent person scheme.

Hand tools laid out ready for roof repair work

Repairs

What repairs might be needed after spray foam removal?

Many roofs need nothing more than a clean down and new insulation after spray foam removal. Others need some work first, such as underlay repairs, timber treatment or replacement, reopened eaves vents or an electrician's check. Small repairs are far easier now than once new insulation is boarded over.

  • Underlay repairs, or a new membrane if it's badly damaged
  • Damp or decayed timber treated, repaired or replaced
  • Eaves and ridge ventilation reopened or added
  • Electrical checks on cables that were buried in foam

Our spray foam removal cost guide explains how a fair quote separates removal, repairs and new insulation.

Choosing a route

What to put back after spray foam removal: cold loft or warm roof?

The first choice after spray foam removal is where the new insulation goes. A loft used only for storage can often go back to a ventilated cold loft, with Which? recommending 270mm of insulation on the floor. If the loft is a room, the insulation goes back in the roof slope, which needs more careful moisture control.

Cold loft

Insulate the loft floor

Insulation goes between and over the ceiling joists, and the roof space above is ventilated again. Which? (6 October 2026) gives 270mm as the recommended loft insulation thickness. Planning Portal warns against blocking eaves ventilation. Thick rolls such as the Thermafleece sheep's wool roll (CosyWool Roll, formerly EcoRoll) suit this route; see our sheep's wool loft insulation page.

Warm roof

Insulate the roof slope

Insulation goes between and under the rafters, so the loft stays inside the heated part of the house. Depth is limited by the rafters and headroom, so thinner, higher-performing layers such as multifoil insulation or rigid boards are often combined. The ventilated gaps and vapour control layer described in BS 5250 have to be designed in from the start.

The HSE report's modelling found that following the BS 5250:2021 guidance "is likely to result in a moisture-safe design".

Diagram comparing a cold loft, with insulation on the loft floor and air flowing through the roof space, and a warm roof, with insulation along the rafters keeping the loft inside the heated part of the house
The two routes after removal: insulate the loft floor and keep the roof space ventilated, or insulate along the rafters to keep the loft warm.

Side by side

Which insulation can replace spray foam?

What goes back after spray foam removal depends on the route. Wool rolls suit a cold loft floor, where Approved Document L's example reaches 0.16 W/m²K with 250mm of mineral fibre. On a roof slope, depth is limited by the rafters, so thinner multifoil or rigid PIR board usually does the work.

Manufacturers' published figures. Multifoil is rated by R-value, so it can't be compared directly with the conductivity figures. Not all of these are products we fit; see our loft insulation options.
OptionPublished thermal figureRoute after removalWhat to check first
Sheep's wool roll0.039 W/mK (CosyWool Roll technical datasheet v6, June 2024, copy hosted by Celtic Sustainables)Cold loft floor, or between raftersEaves vents reopened; enough depth above the joists
Glass mineral wool0.040 to 0.044 W/mK (Knauf, 2024)Cold loft floorLoft ventilation working again
MultifoilSF40: core R 2.66; 3.63 in a roof with two air spaces (SuperFOIL)Warm roof, under the raftersMembrane type, so the air gaps can be designed
Rigid PIR board0.022 W/mK (Celotex GA4000, 2020, copy hosted on Shopify)Warm roof, between or under raftersRafters sound and clean of foam residue, so boards fit tight

A real U-value depends on the whole roof build-up, including air gaps and timbers. Fire ratings, costs and fitting details for each product are on the sheep's wool and multifoil pages.

Building regulations

Do building regulations apply after spray foam removal?

They can. In England, laying loft insulation on its own is exempt from notification. Stripping a roof slope back to the rafters and rebuilding it counts as renovating a thermal element under Approved Document L, and if that covers more than half the roof, the whole roof should usually reach a U-value of 0.16 W/m²K.

Insulating a loft floor is usually exempt, while rebuilding a roof slope after foam removal can bring in Part L and building control.

The exemption is in Schedule 4 of the Building Regulations 2010 (legislation.gov.uk, checked November 2026). It covers insulation in a roof or loft space where the work is solely that insulation and isn't done to comply with another requirement of the regulations. Planning Portal adds that significant changes to walls, roofs or floors would normally need building regulations approval.

Whether your job counts is a question for your local building control team, and it's worth asking before work starts. These rules apply in England. Wales, Scotland and Northern Ireland have their own building and waste regulations, so check with your local council.

The figures come from Approved Document L, Volume 1 (2021 edition, incorporating 2023 amendments):

  • Paragraph 11.2 includes "stripping down the element to expose basic structural components (e.g. bricks, blocks, rafters, joists, frame) and then rebuilding" as renovation
  • Paragraph 11.3: if more than 50% of the element is renovated, the whole roof should reach a U-value of 0.16 W/m²K (Table 4.3)
  • Where headroom limits this, the insulation plus any air gap should at least fill the rafter depth, using the best practicable insulant
  • A lesser standard can apply if 0.16 isn't technically feasible or wouldn't pay back within 15 years (paragraph 4.13)
  • Renovation work should also meet Part C, which covers condensation, among other parts

How we work

How do we handle the work after removal?

After spray foam removal, we show you what we've found, explain what it means for your roof, and recommend the insulation that suits it. If repairs are needed, they're explained and agreed with you before anything extra goes ahead.

We start by showing you what the exposed roof looks like, with photos of what we've found. Any repairs are explained and agreed with you before they go ahead.

We then suggest the insulation that fits your roof, ventilation and budget, and give you a written quote showing the product, the depth and where it's going.

If you haven't had the foam removed yet and are weighing up doing it yourself, read our guide to removing spray foam yourself first. If you're still deciding whether it needs to come out, our guide, Is spray foam insulation bad?, covers when it does and doesn't.

FAQs

After removal questions

What people ask once the foam has gone.

Foam coming out soon?

Talk to us about what should go back in.

Get advice
What should I put back after spray foam removal?

It depends on how you use the loft and how the roof is built. Lofts used for storage often go back to insulation on the floor, such as sheep's wool or mineral wool, with the roof space ventilated. Rooms in the roof usually need rafter-level insulation, often multifoil or rigid board combined with a designed air gap.

Do I need to replace the roof membrane after spray foam removal?

Only if it's damaged, missing or unsuitable for the insulation you choose. An intact membrane or felt can usually stay. Replacing it from outside means lifting the roof covering, which GOV.UK lists as work that normally needs building control notification.

Does my loft need ventilation after spray foam removal?

A cold loft needs air moving through it, usually from the eaves, and foam often blocked those vents. With a warm roof under bitumen felt, BS 5250 guidance (as summarised in the 2024 HSE report) calls for a ventilated gap of at least 40mm once drape is allowed for.

Do I need building regulations approval to replace the insulation?

Loft insulation on its own is exempt from notification in England. Stripping a roof slope back to the rafters and rebuilding it counts as renovation under Approved Document L, and other work such as re-roofing usually needs an application. Check with your local building control team.

How thick should the new loft insulation be?

Which? gives 270mm as the recommended thickness for loft insulation. Approved Document L's examples use 250mm of mineral fibre to reach 0.16 W/m²K at ceiling level. Different materials need different depths, so we tell you the product and depth in the quote.

After removal

Get the right insulation back in